APPROVED |
Includes vibration (ASTM D999), Incline Impact (ASTM D880) and static compression testing (ASTM D642). |
|
|
|
PASSED |
No natural resonance frequency found at standard truck
stimuli frequencies. |
|
|
PASSED |
The test was run at an aggressive test level of .45 G's rms.
for a total of eight hours with no container damage. |
|
|
PASSED |
The Arena Shipper was compressed to a maximum of 30,000 lb.
with no damage and then cycled 63 times up to its rated stack limit
of 9,000 lb. with no damage. |
|
|
PASSED |
500 rotational edge drops were performed from both the 48"
and 45" sides by raising the Arena Shipper 8 to 18 inches off the
floor on one edge and dropping it. No damage was
noted. |
|
|
PASSED |
The Arena Shipper was subjected to 48 consecutive impacts at
10 G's, 40 milliseconds in duration or 5.5 mph. Procedure consisted
of 2 hits on a side followed by a 90 degree rotation repeated 24
times for a total of 48 hits. No damage was noted. |
|
|
PASSED |
The Arena Shipper has achieved a five year projected life
with a worst case distribution cycle consisting of the previous 4
ASTM tests listed. The basis of this test was one cycle per month
for five years or a total of sixty cycles. |
|
|
PASSED |
The Arena Shipper was restrained top and bottom and
pressurized with water to a maximum of 6.0 psi before sustaining
damage |
|
|